Thứ Sáu, 27 tháng 2, 2015

CGDSW-S2-□□ - Water Gate Opening Indicator - Signal Converter - Takuwa Vietnam - STC Vietnam

Water Gate Opening Indicator

Water gate indicator is important equipment for control of water gate on dam and river weir etc.
We have a lineup of indicators and converters which are suitable for purpose and site condition.

Signal Converter (CGDSW Series)

CGDSW series is a signal converter from Synchro to Digital for output to external equipment.
It has many useful functions for adjustment of gate opening indicator.
Non-linearity scale conversion table can be set up and it is suitable for the radial gate.
     

Features

  •   ・Conversion from the Synchro to the BCD signal (by Absolute value)
  •   ・Arbitray scale adjustment (Zero adjustment, Free scale, Level offset)
  •   ・Non-linearity scale conversion table can be set up easily by PC software and installed
          it to the CGDSW through the SD card
  •   ・Self-Diagnosing function (ERR code is displayed)
  •   ・Small size and lightweight
     

Available sites

  •  ・Water gate opening indicator which is using a synchronous motor

Main Specification


TypeCGDSW-S1-□□CGDSW-S2-□□
Power Supply
AC90V~AC242V, 50/60Hz
Current consumption
30VA or less
Ambient temperature
-10ºC ~ 50ºC
Data output rang
±99999
Conversion accuracy±0.1%FS±0.003%FS
Input signalSynchro 3-wire signal
Max.90V/Input synchro
1unit (1st gear)
Synchro 3-wire signal
Max.90V/Input synchro
2unit(2nd gear)
Data output signal
1.BCD: 5digit x 2
 -Each digit odd parity, BUSY, Signal error,Dropping voltage
 -Output condition: A contact with non-voltage
2.RS-232C(no control sequence) x 1
3.Power discontinuity contact x 1
 -Output condition: Make when electric outage
4.Compare contact: x 16
  -Output condition: A contact with non-voltage 
Input scale conversion0~1999/Rev0~20000/Rev
Throughput performance                
Level calculation: -999.99m~+999.99m
Hold: maximum / minimum
Zero point adjustment: by setting SW in the front of body
Data output direction can be set
Self-diagnosing trouble: power off, signal error, dropping voltage
Non-linearity scale conversion by correction table
SD card
Usable card: 2GB or less
Data transfer distance
Input: Max. 1km (2mm2 wire in use)

 

Options

 
  Model Name: CGDSW-[AB]-[CD]
CodeOption TypeOption Detail Number
[AB]Input signalS1: Synchro 3-wire signal Max.90V/Input synchro 1unit
S2: Synchro 3-wire signal Max.90V/Input synchro 2units
[CD]Output signal11: BCD Output x 1 Compare contact output x 1
20: BCD Output x 2

Không có nhận xét nào:

Đăng nhận xét